Worthington Distribution Knowledge Base

Initiating ESI RP Programming with a Keypad or Remote

Introduction:

ESI’s motor controllers and RQ-embedded motors fully support their RP family of input devices. This includes keypads, remote controls, sun/wind inputs, contact-closure switch interfaces, RS-232 via the R2D7, and more. To program the RP options of the controllers or motors, you will need to use a 24-channel keypad or remote control. This article will walk you through initiating programming. We will provide a programming example in a separate article.

 

Requirements:

  • 24-channel ESI Keypad (ESIK24ST or ESIK24STRF433)  or 24-channel ESI Remote Control (ESIT24S or ESIT24SDUAL433)
  • IR or RF receiver for the above items, as appropriate
  • ESI RP60/RQ60 motor controllers or RQ-motors

 

Procedure:

To initiate RP programming, you will need to perform what’s known as a stop-seven-seven (noted as S+7+7 in ESI’s documentation). This means that you press and hold STOP and then press open 7 and close 7 simultaneously while holding STOP and then release. The LED in the upper left of the keypad/remote will begin blinking.

 

Results:

You should now understand what S+7+7 means and be able to start programming the RP options on your controllers and/or motors. If the LED doesn’t begin blinking, or if the LED times out, simply reattempt the S+7+7.

 

 

This article was uploaded by John Zitzelman on 4/28/16

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Replacing an ESI AC Motor Control Board
Viewed 6271 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with SmartThings
Viewed 4426 times since Wed, Jul 12, 2017
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 11671 times since Tue, Jun 20, 2017
Z-Wave Shades – Zipato Micromodule Motor Controller with Zipato
Viewed 2783 times since Wed, Jul 12, 2017
Resetting a Somfy 110VAC RTS Motor and Setting Limits in Program Mode
Viewed 16469 times since Fri, May 6, 2016
Resetting a Somfy 24VDC RTS Motor and Setting Limits in Program Mode
Viewed 5248 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Wink
Viewed 3229 times since Wed, Jul 12, 2017
ESI Programming Keypad and Remote Control Layout
Viewed 11884 times since Thu, Apr 28, 2016
Adding Somfy RTS Treatments to a Z-Wave Network
Viewed 8415 times since Mon, Apr 24, 2017
Replacing Draper Intelliflex Gen2 Products with ESI
Viewed 4168 times since Fri, May 6, 2016
MENU