Initiating ESI RP Programming with a Keypad or Remote

Introduction:

ESI’s motor controllers and RQ-embedded motors fully support their RP family of input devices. This includes keypads, remote controls, sun/wind inputs, contact-closure switch interfaces, RS-232 via the R2D7, and more. To program the RP options of the controllers or motors, you will need to use a 24-channel keypad or remote control. This article will walk you through initiating programming. We will provide a programming example in a separate article.

 

Requirements:

  • 24-channel ESI Keypad (ESIK24ST or ESIK24STRF433)  or 24-channel ESI Remote Control (ESIT24S or ESIT24SDUAL433)
  • IR or RF receiver for the above items, as appropriate
  • ESI RP60/RQ60 motor controllers or RQ-motors

 

Procedure:

To initiate RP programming, you will need to perform what’s known as a stop-seven-seven (noted as S+7+7 in ESI’s documentation). This means that you press and hold STOP and then press open 7 and close 7 simultaneously while holding STOP and then release. The LED in the upper left of the keypad/remote will begin blinking.

 

Results:

You should now understand what S+7+7 means and be able to start programming the RP options on your controllers and/or motors. If the LED doesn’t begin blinking, or if the LED times out, simply reattempt the S+7+7.

 

 

This article was uploaded by John Zitzelman on 4/28/16

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Z-Wave Shades – Zipato Micromodule Motor Controller with Wink
Viewed 7027 times since Wed, Jul 12, 2017
Resetting a Somfy 24VDC RTS Motor and Setting Limits in Program Mode
Viewed 11991 times since Fri, May 6, 2016
ESI RP Programming Example – Calibrating Motor Controllers
Viewed 5357 times since Thu, Apr 28, 2016
ESI Programming Keypad and Remote Control Layout
Viewed 17512 times since Thu, Apr 28, 2016
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 14872 times since Tue, Jun 20, 2017
ESI QSIB Hookup and Programming
Viewed 7781 times since Thu, Jun 22, 2017
Z-Wave Shades – Zipato Micromodule Motor Controller with Fibaro
Viewed 6040 times since Wed, Jul 12, 2017
Adding Somfy RTS Treatments to a Z-Wave Network
Viewed 15390 times since Mon, Apr 24, 2017
Replacing an ESI AC Motor Control Board
Viewed 15666 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with SmartThings
Viewed 9198 times since Wed, Jul 12, 2017
MENU