Introduction:
In this article we will describe how to use the wireless bridge from Luxul to get an Omni Panel (and optionally the Notifier) on a network when running the Cat 5e/6 cable to it is not feasible.  We assume that there is good WiFi coverage in the area where the bridge will be placed.

Requirements:

  • Luxul XVW-P30 Bridge/Range Extender
  • Web browser for configuration

First plug in the bridge.  While it is booting, set your laptop (or whatever device you are configuring with) to a static IP of 192.168.0.5.  Open a web browser and go to 192.168.0.11 and enter admin for the username and the password.  Set the unit to Bridge mode and select your wireless network from the list.  Enter the password for that network.  Click Save and the bridge will apply the settings.

Remove the static IP that you set your laptop back to.  Connect the Omni to one of the ports on the bridge, and if you have a Notifier, connect it to the other port.  Now address the Omni from the keypad as you normally would.

Results:
You should now be able to access the Omni over a network just as if it were connected to a wired switch.

This article written by Richie Scholl.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Port Forwarding for Leviton Omni Systems
Viewed 4238 times since Mon, Apr 4, 2016
HLC/UPB tips on system troubleshooting
Viewed 7799 times since Fri, May 20, 2016
Creating a Virtual Thermostat within the Zipato interface.
Viewed 9793 times since Tue, Jul 12, 2016
Wink: detect a water leak > sound a sounder and notify a user
Viewed 3447 times since Thu, May 18, 2017
Voice Controlled Automation
Viewed 5059 times since Thu, Jul 20, 2017
Omnistat 2 (RC 1000) minimum temperature settings
Viewed 1818 times since Tue, Feb 21, 2017
Programmatically Beeping an Omni Console
Viewed 2969 times since Tue, Apr 5, 2016
Schlage 468 Z-Wave Lock Integration With Leviton VRC0P Serial Interface
Viewed 8303 times since Thu, Mar 9, 2017
Z-Wave common practices and FAQ’s
Viewed 4348 times since Thu, May 12, 2016
PIR troubleshooting guide
Viewed 3906 times since Fri, Jul 15, 2016
MENU