Z-Wave Shades – Zipato Micromodule Motor Controller with Zipato

Introduction:

Looking to control some shades with Z-Wave? Worthington Distribution has a solution using a Somfy standard, 4-wire, AC motor with Zipato’s Micromodule Motor Controller. This article will walk you through the shade installation as well as how to add the shade to your Zipato hub.

 

Requirements:

  • Somfy-powered shade using a standard, 4-wire, AC motor
  • Zipato Micromodule motor controller, SKU ZIPPHPAN08US
  • Zipato hub

 

Procedure:

Pre-wiring recommendations –

It’s recommended that you have your electrician run an AC wire to the left side of the window. Although a bare wire with wire nuts can be used, to pass inspection, the electrician will likely need to terminate the AC line. If there’s no room for a standard outlet, your electrician can install a Sillites self-contained receptacle, SILSCRW.

 

Install the shade per the fabricator’s instructions. Be sure that the shade is level to avoid any issues with the fabric “telescoping.”

 

Install the Zipato Micromodule Motor Controller, following the diagram below:

Please note: Z-Wave is an RF communication. If your shade has a metal fascia or a cassette, make sure that the antenna of the micromodule is outside of the metal to ensure optimal Z-Wave communication.

 

Perform the following steps to learn the micromodule into your Zipato hub:

  1. Log into the Zipato browser interface.
  2. Click on the Device Manager and select “ADD NEW DEVICE.”
  3. Select Z-Wave.
  4. While the device exclusion window is open, apply power to the micromodule. It should be detected by the Zipato. If it isn’t, quickly press the button on the module three times.
  5. The module should learn into your Wink hub. If it doesn’t, then quickly press the button on the module three times again.
  6. Name the device and click “Done.”
  7. Give the module approximately 60 seconds to complete provisioning before proceeding.
  8. Click on Open or Close to ensure that the shade moves in the correct direction.1 Also, make sure that the shade stops at the correct upper and lower limits.2

 

1 If the shade runs in reverse, power down the micromodule and swap the red and black wires coming from the motor. Make sure to re-apply power once the wires have been swapped.

2 If the limits need to be adjusted, refer to the shade fabricator’s or the motor manufacturer’s instructions.

 

Once you’re certain that the directions and limits are correct, you will need to calibrate the micromodule to the shade. To do so, press and hold the button on the micromodule for 3-5 seconds and then release it. The shade will move up and down several times so that the module can learn its upper and lower limits.

 

Repeat these steps for any additional shades and micromodules you would like to control.

 

Results:

You will now have full control of the shade with your Z-Wave controller. To confirm, press Open, Close, or move to % to verify that the treatment now moves to this position.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Adjusting Limits on a Somfy RTS Motor
Viewed 22500 times since Fri, May 6, 2016
Replacing an ESI AC Motor Control Board
Viewed 15666 times since Fri, May 6, 2016
Adding Somfy RTS Treatments to a Z-Wave Network
Viewed 15390 times since Mon, Apr 24, 2017
Resetting a Somfy 24VDC RTS Motor and Setting Limits in Program Mode
Viewed 11991 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Wink
Viewed 7027 times since Wed, Jul 12, 2017
Creating a Virtual Thermostat within the Zipato interface.
Viewed 31783 times since Tue, Jul 12, 2016
ESI QSIB Hookup and Programming
Viewed 7781 times since Thu, Jun 22, 2017
Initiating ESI RP Programming with a Keypad or Remote
Viewed 7151 times since Thu, Apr 28, 2016
Zipato Rules Creator Overview
Viewed 12619 times since Wed, Jun 15, 2016
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 14872 times since Tue, Jun 20, 2017
MENU