Introduction:

Looking to control some shades with Z-Wave? Worthington Distribution has a solution using a Somfy standard, 4-wire, AC motor with Zipato’s Micromodule Motor Controller. This article will walk you through the shade installation as well as how to add the shade to your Zipato hub.

 

Requirements:

  • Somfy-powered shade using a standard, 4-wire, AC motor
  • Zipato Micromodule motor controller, SKU ZIPPHPAN08US
  • Zipato hub

 

Procedure:

Pre-wiring recommendations –

It’s recommended that you have your electrician run an AC wire to the left side of the window. Although a bare wire with wire nuts can be used, to pass inspection, the electrician will likely need to terminate the AC line. If there’s no room for a standard outlet, your electrician can install a Sillites self-contained receptacle, SILSCRW.

 

Install the shade per the fabricator’s instructions. Be sure that the shade is level to avoid any issues with the fabric “telescoping.”

 

Install the Zipato Micromodule Motor Controller, following the diagram below:

Please note: Z-Wave is an RF communication. If your shade has a metal fascia or a cassette, make sure that the antenna of the micromodule is outside of the metal to ensure optimal Z-Wave communication.

 

Perform the following steps to learn the micromodule into your Zipato hub:

  1. Log into the Zipato browser interface.
  2. Click on the Device Manager and select “ADD NEW DEVICE.”
  3. Select Z-Wave.
  4. While the device exclusion window is open, apply power to the micromodule. It should be detected by the Zipato. If it isn’t, quickly press the button on the module three times.
  5. The module should learn into your Wink hub. If it doesn’t, then quickly press the button on the module three times again.
  6. Name the device and click “Done.”
  7. Give the module approximately 60 seconds to complete provisioning before proceeding.
  8. Click on Open or Close to ensure that the shade moves in the correct direction.1 Also, make sure that the shade stops at the correct upper and lower limits.2

 

1 If the shade runs in reverse, power down the micromodule and swap the red and black wires coming from the motor. Make sure to re-apply power once the wires have been swapped.

2 If the limits need to be adjusted, refer to the shade fabricator’s or the motor manufacturer’s instructions.

 

Once you’re certain that the directions and limits are correct, you will need to calibrate the micromodule to the shade. To do so, press and hold the button on the micromodule for 3-5 seconds and then release it. The shade will move up and down several times so that the module can learn its upper and lower limits.

 

Repeat these steps for any additional shades and micromodules you would like to control.

 

Results:

You will now have full control of the shade with your Z-Wave controller. To confirm, press Open, Close, or move to % to verify that the treatment now moves to this position.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
ESI QSIB Hookup and Programming
Viewed 747 times since Thu, Jun 22, 2017
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 9360 times since Tue, Jun 20, 2017
Creating a Virtual Thermostat within the Zipato interface.
Viewed 3121 times since Tue, Jul 12, 2016
Zipato RFID Keypad Setup
Viewed 2610 times since Fri, Apr 29, 2016
Replacing Draper Intelliflex Gen2 Products with ESI
Viewed 1815 times since Fri, May 6, 2016
Voice Controlled Automation
Viewed 2247 times since Thu, Jul 20, 2017
Z-Wave common practices and FAQ’s
Viewed 2544 times since Thu, May 12, 2016
ESI RP Programming Example – Changing the Main Address
Viewed 3318 times since Thu, Apr 28, 2016
How to create a Z-Wave network with the Leviton VRC0P-1LZ
Viewed 3610 times since Tue, Jul 26, 2016
Replacing an ESI AC Motor Control Board
Viewed 4167 times since Fri, May 6, 2016
MENU