Worthington Distribution Knowledge Base

Schlage 468 Z-Wave Lock Integration With Leviton VRC0P Serial Interface

In this example we will review the steps needed to perform a manual reverse association with a Schlage 468 lock to a Leviton VRC0P Serial Interface. The reverse association is required for two-way communication between the lock and Serial Interface. This means if the lock changes state manually (locking or unlocking) this will be reported to the Serial Interface.

 

Requirements
• Leviton VRUSB Programming USB Stick
• Leviton VRC0P Serial Interface Verison +3
• Leviton Vizia RF Installer software version 1.1.2.0 (www.leviton.com/rfinstaller)
• PC With Windows 7 or less (XP, Vista, etc .)
• Schlage 468 Motorized Deadbolt

 

1. Include Devices
2. Set Standard Reverse Associations
3. Open the “Diagnostics” menu and select “Routing Slave Associations”
4. Select Routing Slave
5. Associate the Serial Interface
6. Additional Locks

 

 

Include Device:

-Include lock and all other devices tobe part of the network, including the VRC0P last.
-To Include, select the include buttonon the top, press OK then enter the “Programming Code” that comes with

 


the lock, followed by pressing “0.”

 

 

-Set associations to all other devices except 468 locks.

-This will typically be two-way communicating devices such as Vizia RF lights and thermostats.

Right click on the Serial Interface and select “RS232 Setup.”

-Select the devices to associate EXCEPT the 468 lock(s) and click ”Set Association. “

 

 

Open Diagnostics and select Routing Slave Associations
-Select Routing Slave
-You will need to be near the lock you are associating.
-Set “Routing Slave” to the 468 lock you wish to associate to the Serial Interface.
-This will retrieve association information from all of the devices and populate
them in the “Non-Associated Devices” column.
-Open the “Diagnostics” menu and select “Routing Slave Associations.”

 

Select Routing Slave

-You will need to be near the lock you are associating.
-Set “Routing Slave” to the 468 lock you wish to associate to the Serial Interface.
-This will retrieve association information from all of the devices and populate them in the “Non-Associated Devices” column.

Associate the Serial Interface

 -Under “Non-Associated Device(s)” click on the serial interface to highlight.
-Click the top or left green arrow to move the serial interface to the “AssociatedDevice(s)” column.

-Once the Serial Interface appears in the “Associated Devices” column the action is completed
and is denoted as “Finished” in the lower left corner of the window.

 Additional Locks

- To associate additional locks, select the next routing slave to be associated with the serial interface.
-Click the “left” green arrow to move the serial interface to the “Associated Device(s)” column.

 

 You should now be able to control your locks as well as see the status of it.

If you have any questions or issues, please give us a call at 800-282-8864 or email sales@worthdist.com

 

This article was created by Joel DeYoung - Technical Sales

 

 

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
How to create a Z-Wave network with the Leviton VRC0P-1LZ
Viewed 15925 times since Tue, Jul 26, 2016
Wink: detect a water leak > sound a sounder and notify a user
Viewed 18252 times since Thu, May 18, 2017
Using the Aeotec Wallmote with SmartThings
Viewed 31929 times since Tue, Mar 21, 2017
Zipato RFID Keypad Setup
Viewed 10491 times since Fri, Apr 29, 2016
Z-Wave common practices and FAQ’s
Viewed 16064 times since Thu, May 12, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Zipato
Viewed 6568 times since Wed, Jul 12, 2017
Z-Wave Shades – Zipato Micromodule Motor Controller with Fibaro
Viewed 6041 times since Wed, Jul 12, 2017
Using the Luxul Range Extender/Bridge on the Omni Ethernet Port
Viewed 8124 times since Wed, Apr 27, 2016
Synchronizing on the Zipato Controller
Viewed 6006 times since Thu, Oct 13, 2016
Troubleshooting OmniStat2 Communication Issues
Viewed 6817 times since Thu, Aug 11, 2016
MENU