Resetting a Somfy 110VAC RTS Motor and Setting Limits in Program Mode

Introduction:

There are times when you will need to restore a 110VAC RTS motor to its factory defaults, such as when the motor’s remote control has been lost and needs to be replaced. This article will walk you through resetting the motor to a factory default and, once defaulted, setting the upper and lower limits. To adjust the limits on a motor operating in User mode, see our article “Adjusting Limits on a Somfy RTS Motor.”

 

Requirements:

  • Installed Somfy 110VAC RTS Motor
  • Paper clip
  • Somfy Handheld Remote Control (i.e. Telis 1 or Telis 4)

 

Procedure:

*** IMPORTANT ***

Since Somfy RTS motors use the same procedure to learn and forget a transmitter you MUST power only one motor at a time when configuring Somfy channels.

 

To reset the motor and pair it with your remote control:

  1. Start with having power applied to the motor.
  2. Remove the power for 2 seconds.
  3. Re-apply power for 10 seconds.
  4. Remove the power for 2 seconds.
  5. Re-apply power. The shade will begin to move.
  6. When it stops moving, press and hold the programming button on the back of the remote until the treatment jogs twice. Do not release until the shade jogs twice or you will have to restart the power-cut process.

 

The motor is now reset, in programming mode, and paired with your remote control.

 

To set the limits of the motor and put it into User mode:

  1. Check that the motor direction is correct (UP moves the treatment up, and DOWN moves it down). If incorrect, reverse the motor direction by pressing and holding MY/STOP until the motor jogs.
  2. Move the treatment to the desired upper limit. Press and hold MY/STOP and DOWN until the treatment starts to move. If it stops on button release, you'll have to redo this step.
  3. Once the treatment starts to travel down by itself, press the MY/STOP button when it gets close to the desired lower limit.
  4. Move the treatment to the desired lower limit and then press MY/STOP and UP until the treatment begins to move. If it stops on button release, you'll have to redo this step.
  5. Press and hold the MY/STOP button until the treatment jogs to commit the limits to memory.
  6. Press and hold the Programming button on the back of the remote until the treatment jogs to put the shade into User mode.

 

Results:

The motor is now paired with your remote control and operating normally. Press up and down to confirm that the treatment moves to the upper and lower limits.

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
ESI Programming Keypad and Remote Control Layout
Viewed 11291 times since Thu, Apr 28, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Fibaro
Viewed 2623 times since Wed, Jul 12, 2017
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 11505 times since Tue, Jun 20, 2017
Replacing an ESI AC Motor Control Board
Viewed 6049 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Zipato
Viewed 2577 times since Wed, Jul 12, 2017
Adjusting Limits on a Somfy RTS Motor
Viewed 3847 times since Fri, May 6, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Wink
Viewed 2949 times since Wed, Jul 12, 2017
ESI RP Programming Example – Setting Group Channels
Viewed 3477 times since Thu, Apr 28, 2016
Z-Wave Shades – Zipato Micromodule Motor Controller with Vera Controls
Viewed 3408 times since Wed, Jul 12, 2017
Resetting a Somfy 24VDC RTS Motor and Setting Limits in Program Mode
Viewed 4867 times since Fri, May 6, 2016
MENU