ESI RP Programming Example – Calibrating Motor Controllers

Introduction:

ESI’s motor controllers and RQ-embedded motors fully support their RP family of input devices. This includes keypads, remote controls, sun/wind inputs, contact-closure switch interfaces, RS-232 via the R2D7, and more. To program the RP options of the controllers or motors, you will need to use a 24-channel keypad or remote control. This article will walk you through one of the most common RP programming steps, calibrating a motor controller. The layout of the keypad/remote control and initiating programming are explained in separate articles.

 

Requirements:

  • 24-channel ESI Keypad (ESIK24ST or ESIK24STRF433) or24-channel ESI Remote Control (ESIT24S or ESIT24SDUAL433)
  • IR or RF receiver for the above items, as appropriate
  • ESI RP60/RQ60 motor controllers or RQ-motors
  • RP Programming Summary which is appropriate for the controller(s) or motor(s) you will be programming. These can be found on ESI’s website or are available through Worthington Distribution.

 

Procedure:

If you are replacing an ESI controller in an existing system, you will need to calibrate the controller to the existing motor to enable intermediate stops.

 

To begin, open the RP Programming Summary and find the table entry labeled “Calibrate the travel time.” Then simply follow the steps in order from left to right.

 

 

For example, if I was calibrating the controller which responds to channel 9 on the customer’s remote control, I would follow these steps:

  1. Press STOP, Open 7, and Close 7 simultaneously. The LED on the keypad/remote will begin blinking.
  2. Press Open 9. The LED on the controller will light solid red and the LED on the keypad/remote will stop blinking.
  3. Press Close 10. The LED on the controller will blink off once.
  4. Press Open 10. The LED on the controller will blink off once.
  5. The treatment will run to its upper an lower limits several times and will then stop. The controller will then exit programming mode automatically.

 

Results:

The controller has now learned the upper and lower limits of the motor it is connected to. This can be confirmed by setting intermediate positions in RP programming or by sending it move-to position commands via RQ.

 

 

 

 This article was uploaded by John Zitzelman on 4/28/16

 

Attached Files
There are no attachments for this article.
Comments
There are no comments for this article. Be the first to post a comment.
Name
Email
Security Code Security Code
Related Articles RSS Feed
Z-Wave Shades – Zipato Micromodule Motor Controller with Zipato
Viewed 6567 times since Wed, Jul 12, 2017
ESI Programming Keypad and Remote Control Layout
Viewed 17512 times since Thu, Apr 28, 2016
Resetting a Somfy 24VDC RTS Motor and Setting Limits in Program Mode
Viewed 11991 times since Fri, May 6, 2016
Replacing Draper Intelliflex Gen2 Products with ESI
Viewed 8520 times since Fri, May 6, 2016
ESI RP Programming Example - Setting Intermediate Positions on the First Group Channel
Viewed 14872 times since Tue, Jun 20, 2017
ESI QSIB Hookup and Programming
Viewed 7781 times since Thu, Jun 22, 2017
Z-Wave Shades – Zipato Micromodule Motor Controller with Wink
Viewed 7027 times since Wed, Jul 12, 2017
Adjusting Limits on a Somfy RTS Motor
Viewed 22500 times since Fri, May 6, 2016
Adding Somfy RTS Treatments to a Z-Wave Network
Viewed 15390 times since Mon, Apr 24, 2017
ESI RP Programming Example – Changing the Main Address
Viewed 7585 times since Thu, Apr 28, 2016
MENU